content="14/09/2022″/> Force transducer DMS 727, ± 0,5 %, 50 N ~ 10 KN

Force transducer DMS 727, ± 0,5 %, 50 N ~ 10 KN

Force transducer DMS 727, ± 0,5 %, 50 N ~ 10 KN
Article code727
0 star(s) in 0 review(s) Write a review
- Fmax: 50 N to 10 kN
- very small dimensions
- suitable for compression or tension and compression force  
- can be used for static and dynamic force  
- high natural frequency
- housing material: stainless steel
- various applications in environments like micro mechanics, bio-techniques, pharmaceutical industries, etc.

Characteristics
- combined error: ≤ ± 1 % Fmax
- creep error after 30 min.: ≤ ± 0,15 % Fmax
- temperature effect per 10 K
 a) of zero: ≤ ± 0,2 %
 b) of sensitivity: ≤ ± 0,4 %
- nominal sensitivity: ~1,5…2 mV/V
- input resistance: 340…420 Ω
- output resistance: 300…370 Ω
- insulation resistance: > 5 GΩ
- zero balance: 0,5 %
- recommended supply voltage: 5 V
- nominal range of supply voltage: 2...5 V
- maximum supply voltage: 8 V
- service load: 100 % Fmax
- max permissible load: 110 % Fmax
- breaking load: > 200 % Fmax
- maximum side load: 3 % Fmax
- max permissible dynamic load: 70 % Fmax
- displacement at nominal load: 0,1 mm
- reference temperature: +23°C
- nominal temperature range: -10 ... +50°C
- service temperature range: -20 ... +60°C
- storage temperature: -20 ... +80°C
- protection class (DIN 40050): IP 56
- material of the measuring body: stainless steel
- cable length: 1 m

Reviews

There are no reviews available in your current language
Write a review
Get the best deals for your location; Select your country