content="14/09/2022″/> Force transducer DMS 721, ± 0,1 %, 1 kN ~ 10 kN

Force transducer DMS 721, ± 0,1 %, 1 kN ~ 10 kN

Force transducer DMS 721, ± 0,1 %, 1 kN ~ 10 kN
Force transducer DMS 721, ± 0,1 %, 1 kN ~ 10 kN
Article code721
- Fmax: 1, 2, 5 or 10 kN
- low profile
- suitable for tension and compression force  
- can be used for static and dynamic force
- high dynamic permissible load  
- measuring body:
 1 & 2 kN:  aluminium
 5 & 10 kN: stainless steel
- protection class IP67
- options: load button, compression plate, rod end bearings
- customer designs available

Characteristics
- combined error: ≤ ± 0,1 % Fmax
- non-linearity: ≤ ± 0,1 % Fmax
- non-repeatability: ≤ ± 0,05 % Fmax
- creep error after 30 min.: ≤ ± 0,05/0,08 % Fmax
- temperature effect per 10 K
 a) of zero: ≤ ± 0,05 %
 b) of sensitivity: ≤ ± 0,04 %
- nominal sensitivity: 2 mV/V ± 0,25 %
- input resistance: 350 ± 10 Ω
- output resistance: 350 ± 10 Ω
- insulation resistance: > 5 GΩ
- zero balance: 0,5 %
- recommended supply voltage: 10 V
- nominal range of supply voltage: 1 ... 12 V
- maximum supply voltage: 12 V
- service load: 100 % Fmax
- max permissible load: 110 % Fmax
- breaking load: > 200 % Fmax
- maximum side load: 20 % Fmax
- max permissible dynamic load: 70 % Fmax
- displacement at nominal load: 0,2 mm
- reference temperature: +23°C
- nominal temperature range: -10 ... +50°C
- service temperature range: -20 ... +70°C
- storage temperature: -20 ... +80°C
- protection class (DIN 40050): IP 67
- material of the measuring body:
 1 & 2 kN:  aluminium
 5 & 10 kN: stainless steel
- cable length: 5 m
- fixing screws:  M5, 8.8/10.9 Rm, tightening torque 4/6 Nm