content="14/09/2022″/> Force transducer DMS 717, ± 0,25 %, 5 N ~ 30 kN

Force transducer DMS 717, ± 0,25 %, 5 N ~ 30 kN

Force transducer DMS 717, ± 0,25 %, 5 N ~ 30 kN
Article code717
0 star(s) in 0 review(s) Write a review
- Fmax: 5 N to 30 kN
- small dimensions
- suitable for tension or tension and compression force  
- can be used for static and dynamic force
- high natural frequency
- measuring body: special alloy material
- various applications in environments like micro mechanics, bio-techniques, pharmaceutical industries, etc.

Characteristics
- combined error: ≤ ± 0,25 % Fmax
- non-linearity: ≤ ± 0,2 % Fmax
- non-repeatability: ≤ ± 0,1 % Fmax
- creep error after 30 min.: ≤ ± 0,3 % Fmax
- temperature effect per 10 K
 a) of zero: ≤ ± 0,3 %
 b) of sensitivity: ≤ ± 0,4 %
- input resistance: 350 ± 10 Ω
- output resistance: 350 ± 10 Ω
- insulation resistance: > 4 GΩ
- zero balance: 0,8 %
- recommended supply voltage: 5 V
- nominal range of supply voltage: 2 ... 5 V
- maximum supply voltage: 6 V
- service load: 100 % Fmax
- max permissible load: 110 % Fmax
- breaking load: > 200 % Fmax
- maximum side load: 10 % Fmax
- max permissible dynamic load: 70 % Fmax
- displacement at nominal load: 0,1 mm
- reference temperature: +23°C
- nominal temperature range: -10 ... +50°C
- service temperature range: -20 ... +70°C
- storage temperature: -20 ... +80°C
- protection class (DIN 40050): IP 54
- material of the measuring body: special alloy material
- cable length: 0,5 m

For more information, click here