content="14/09/2022″/> Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz

Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz

Free Shipping B,L,F,NL,D

Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz
Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz
Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz
Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz
Sound level meter, class 2, 25~136 dBA, 0.02~12.5 kHz
€ 1,320.00 1,120.00 *Prices are exclusive of VAT
Manufacturer SAUTER GmbH
Article codeSW 2000
Professional sound level meter ideal for measurements for workplaces which are outdoors, e.g. at airports, on building sites, in road construction etc. with broad access to spectrum thanks to the highly-accurate 24-Bit A/D converter
  • floating point evaluation for higher level of accuracy and better stability
  • the optimised analogue frontend switch reduces the ambient noise and increases the linear measuring range
  • a specially-developed algorithm permits a compliant dynamic range of more than 120 dB! (SW 1000: > 123 dB; SW 2000: > 122 dB)
  • three profiles and 14 user-defined measurements can be calculated in parallel with different frequency and time weighting
  • different sound pressure levels can be selected, such as, for example, Laeq, LcPeak, LaF, LaFMax, LaFMin, SD, SEL, E
  • LN statistics and display of the graph showing the progression of time
  • user-defined integral interval measurement up to a maximum of 24 hours is possible
  • frequency weighting (filter) A, B, C, Z
  • time interval during measurement: F (fast), S (slow), I (pulse)
  • freely-definable limits for the output of an optical alarm signal
  • Peak Hold Mode to capture peaks
  • octavo function for targeted sound analysis
  • TRACK function with graphic display of a measurement

Technical data
  • accuracy: class 2 (Group X)
  • Standard:
    * GB/T 3785.1-2010, IEC 60651:1979, IEC 60804:2000
    * IEC 61672-1:2013, ANSI S1.4-1983, ANSI S1.43-1997
  • Octave1:
    * average frequencies of the 1/1-octave filter: 31.5 Hz to 8 kHz
    * GB/T 3241-2010, IEC 61260-1:2014, ANSI S1.11-2004
  • microphone MPA200T:
    * pre-polarised 1/2” measuring microphone
    * class 2
    * sensitivity: 40 mV/Pa
    * frequency range: 20 Hz to 12,5 kHz
  • microphone port: TNC connector with ICCP (4 mA) power supply
  • detector/Filter: fully digital signal processing by floating-point coprocessor (digital detector and filter)
  • integration period
    * user-defined integration period within a range of 1 s–24 h
    * repetition time: indefinite or 1 to 9999.
  • logging step: 0.1 s, 0.2 s, 0.5 s; 1 s to 24 h
  • measuring functions:
    * LXY(SPL), LXeq, LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN.
    X means frequency weighting:
    A, B, C, Z; Y means time constant;
    F, S, I; N means statistic measurement: 1 to 99; 3 profiles and 14 user-defined measurements calculated simultaneously with differ-ent frequency weightings / time constants
  • 24 h measurement: automatic measurement as per the date and time settings defined by the customer, and history data recording
  • frequency weighting: parallel A, B, C, Z
  • time constant: parallel detection of F, S, I and Peak values
  • Own noise:
    * sound: 20 dB(A), 26 dB(C), 31 dB(Z)
    * electrical data: 14 dB(A), 19 dB(C), 24 dB(Z)
  • Upper limit:
    * 136 dB(A)
    * increase up to 154 dB(A) using a 50 mV/Pa microphone 136 dB(A)
  • frequency response: 20 Hz to 12.5 kHz
  • linearity range: 20 dB(A) to 134 dB(A)
  • dynamic range: 122 dB (14 dB(A) to 136 dB(A))
  • peak-C range: 47 dB(A) to 139 dB(A)
  • electrical input: maximum input voltage: 5 Veff (7.07 Vpeak) input impedance of pre-amplifier > 6 GΩ
  • range setting: one range covering the entire dynamic range
  • resolution: 24 bits
  • sampling frequency: 48 kHz
  • time history: displaying noise characteristics as a function of time, duration of measurement: 1 minute, 2 minutes, 10 minutes
  • LCD indicator: LCD display, 160 x 160, with white backlight, 14 contract levels, readouts updated every 1 s
  • bulk storage: microSD (TF) card with a capacity of 4 GB
  • final processing: VA-SLM software for final processing: readout, analysis and report generation based on the data saved
  • data export: direct computer connection to read the content of memory card (as a USB disk)
  • output:
    * AC output (maximum 5 VEFF, ±15 mA)
    * DC output (10 mV/dB, maximum 15 mA)
    * serial RS-232 interface and USB port (USB Disk Mode and Mo-dem Mode)
  • alarm: user-defined LED indicator alarm threshold for alarm status dis-playing
  • setup template: 5 templates for saving of user settings for different applications, the template can be stored in the microSD card
  • automatic activation: automatic activation and initiation of measurement by applying the operating voltage, easy integration
  • power supply: 4 alkaline 1.5 V batteries (LR6/AA/AM3) are sufficient for approx. 10 hours (depending on the battery), the working voltage can also be supplied by a direct current source (7–14 V, 500 mA) and a USB port (5 V, 1 A)
  • real time clock (RTC): integrated buffer battery was factory calibrated with an error of < 26 s in 30 days (< 10 ppm, (25 ±16)°C); the buffer battery ensures an operating continuity of the system clock also during replacement of the main batteries available GPS time function (option with GPS module)
  • language: English, Chinese, Portuguese, Spanish, German, French
  • firmware updating: firmware updated using the USB port
  • environmental conditions:
    * temperature: –10ºC to 50ºC
    * relative humidity: 20–90%
  • real-time temperature: indication of real-time temperature on the main screen
  • dimensions (W×H×D):  70×300×36 mm
  • weight: approx. 620 g with 4 alkaline batteries

Standard delivery
  • SW 2000 sound level meter without microphone
  • ICCP pre-amplifier with TNC connector
  • SW-A01 class 1 microphone
  • Wind shield SW-A03, 90 mm wind shield, diameter up to the micro-phone: 1/2”
  • microSD card SW-A04, 4 GB memory card for data storage
  • 4 alkaline batteries (LR6/AA/AM3)
  • power unit: 230 Vac-9 V/500 mA
  • user's manual (E, D, F, S, I)
  • coffer
In stock
Click here to download the brochure PDF

Accessories
  • ISO calibration certificate (961-281)
  • plug-In for data transfer of measuring data from the measuring instrument and transfer to a PC, e.g. in MS Excel, AFI-1.0
  • tripod stand for the sound level meter L×D×H 430×90×90 <=>1250×750×750 mm, SW-A05
  • GPS: type of receiver: 50-channel receiver time to initial measurement: cold start 27 s, warm start 27 s, hot start 1 s, sensitivity: tracking –161 dBm, new measurement –160 dBm, cold start –147 dBm, hot start –156 dBm horizontal accuracy of position indication: 2.5 m accuracy of time indication: 30 ns, accuracy of speed indication: 0.1 m refreshing frequency: 1 Hz operating range limits: dynamics ≤ 4 g, height < 50,000 m, speed < 500 m/s
  • calibrator: CA111, Class 1, 94 dB/114 dB, 1 kHz, ASU-01
  • foam draft shield, SW-A03
  • printer: thermal mini-printer, RS-232 socket
Get the best deals for your location; Select your country